Rankine Cycle
The Rankine cycle is the ideal thermodynamic cycle for vapor power plants, particularly steam power plants. It models the conversion of heat into work using a working fluid (typically water/steam) that undergoes phase change. The ideal cycle consists of four internally reversible processes: (1) Isentropic compression in a pump (saturated liquid at state 1 to compressed liquid at state 2). (2) Constant-pressure heat addition in a boiler (compressed liquid to superheated vapor at state 3). (3) Isentropic expansion in a turbine (superheated vapor to wet vapor at state 4). (4) Constant-pressure heat rejection in a condenser (wet vapor to saturated liquid at state 1). On a T-s diagram, the Rankine cycle appears as a rectangle-like shape crossing the vapor dome. The area under the heat-addition curve represents q_in, and the area under the heat-rejection curve represents q_out. Net work output equals the difference: w_net = q_in − q_out. Energy analysis uses steam tables or property software to find enthalpy (h) and entropy (s) at each state. For the ideal cycle: pump work w_p = h₂ − h₁ ≈ v₁(P₂ − P₁) for incompressible liquid; turbine work w_t = h₃ − h₄; heat added q_in = h₃ − h₂; heat rejected q_out = h₄ − h₁. Thermal efficiency is η_th = w_net / q_in = (w_t − w_p) / q_in = 1 − q_out / q_in. Real Rankine cycles have irreversibilities: pump and turbine isentropic efficiencies (η_p < 100%, η_t < 100%) reduce net work. Common modifications improve efficiency: (1) Increasing boiler pressure raises average heat-addition temperature but increases moisture at turbine exit. (2) Superheating steam to higher temperatures increases efficiency and reduces turbine-exit moisture (moisture should stay below ~10% to prevent blade erosion). (3) Reheat (expanding in stages with reheating between) increases efficiency and reduces moisture. (4) Regeneration (feedwater heating using extracted steam) increases efficiency by raising average heat-addition temperature. The condenser pressure is limited by the cooling medium temperature (typically 30–40°C for river/ocean cooling), setting a lower bound on T_L. Lower condenser pressure increases efficiency but requires larger condensers and increases moisture content.
Knowledge Check
1.What is the working fluid in a conventional steam Rankine cycle?
2.Which process in the ideal Rankine cycle is isentropic compression?
3.In the ideal Rankine cycle, heat addition in the boiler occurs at constant what?
4.A Rankine cycle has q_in = 2800 kJ/kg and q_out = 1800 kJ/kg. What is the thermal efficiency?
5.For an ideal Rankine cycle, h₁ = 191.8 kJ/kg, h₂ = 200.0 kJ/kg, h₃ = 3200 kJ/kg, h₄ = 2200 kJ/kg. What is the turbine work per kg?
6.Using the enthalpies from the previous question, what is the thermal efficiency?
7.Why is superheating the steam beneficial in a Rankine cycle?
8.What is a typical maximum allowable moisture content at the turbine exit in a steam power plant?
9.How does increasing the boiler pressure affect the ideal Rankine cycle efficiency (all else equal)?
10.What is the purpose of regeneration (feedwater heating) in a Rankine cycle?